3.1.25: USB Communication Failure
PowerWriter Device Connection and Firmware Download Troubleshooting
1. Applicable Symptoms
This document is intended for preliminary troubleshooting when a Power Writer / PowerWriter tool displays any of the following prompts:
Connection failed: Not enough memory resources are available to complete this operation.Failed to open the device port COM9, or the port cannot be opened.
This device port was not recognized. Please refresh the device list and try again.
Please connect the device before performing the operation.
The log keeps showing "Device list refresh completed", but the number of detected devices is unstable, or the device afterwards shows "Disconnected".
Before firmware download, the operation times out, the device is reported as not connected, or the process cannot continue.
Wording may differ slightly between software versions. Always refer to the actual log on your machine.
2. Meaning of the Error
Not enough memory resources are available to complete this operation is a Windows system resource error returned when the device communication port is being opened. It may be related to the serial port driver, port occupation, unstable USB connection, incorrect device enumeration, or an abnormal driver state; it cannot be judged as insufficient physical memory on the PC based on this prompt alone.
"This device port was not recognized" means the software has not found a usable target device port. "Power Writer disconnected" means the connection between the software and the device has been interrupted. At this point, continuing to click Connect or Download will usually only repeat the failure.
3. Troubleshooting Sequence and Solutions
3.1 Stop Repeated Attempts and Re-establish the Connection
- Exit the PowerWriter software and confirm that no other PowerWriter window is still running.
- Close any program that may be using the serial port, such as serial debugging tools, terminal tools, other programming tools, or device management programs.
- With no firmware being written, disconnect the device USB cable, wait a few seconds, and then reconnect it.
- Connect the device directly to the computer USB port first; temporarily remove any docking station, USB hub, or extension cable, and if possible try another USB port or data cable.
- Restart PowerWriter, click "Refresh devices", confirm that the port and device count shown by the software are stable, and then click "Connect device".
3.2 Verify the Windows Device Port
- Open Windows "Device Manager" and expand "Ports (COM & LPT)" and "Universal Serial Bus controllers".
- Observe which device entries appear or disappear when the device is plugged in and out, confirm that the device is recognized by Windows, and note the corresponding COM number.
- If the COM number selected in the software does not match the one shown in Device Manager, select the correct port in the software, then refresh and reconnect.
- If the device in Device Manager has a yellow exclamation mark, is shown as an unknown device, or nothing changes at all when plugging in or out, proceed to step 3 to check the driver and USB connection.
- If the port is displayed normally but still cannot be opened, check whether another program is occupying that COM port. Close the relevant program and reopen PowerWriter.
3.3 Check the Driver and USB Connection
- Install or repair the corresponding USB/serial port driver according to the instructions provided by the device or software supplier. Do not download drivers from unknown websites.
- After installation or repair, restart PowerWriter; if Device Manager is still abnormal, restart the computer and reconnect the device.
- Replace the USB data cable with one confirmed to support data transfer, and try another USB port on the computer. Some cables can only charge and cannot transfer data.
- If a USB hub or docking station is used, connect directly to the computer for testing.
- Only when the software source is confirmed trustworthy and permission-related problems still occur, try starting the software as administrator according to the supplier's instructions.
3.4 Handle Recurring System Resource Errors
After completing the steps above, if Not enough memory resources... still occurs repeatedly:
- Exit PowerWriter and other serial port programs, restart the computer, start only PowerWriter, and then connect the device.
- In Device Manager, confirm that the port has no error flag, and note the device name, driver version, and COM number.
- Perform a comparison test with another data cable or another computer, to determine whether the problem follows the device, the cable, or the current computer.
- Suspend further firmware writing and contact device or software technical support. Provide the materials listed in "Information to Prepare When Contacting Support" in this guide.
Do not modify the registry, arbitrarily delete device drivers, disable security software, or change system memory settings based on this prompt alone. These operations cannot confirm the root cause and may introduce new problems.
Quick Diagnosis
| Symptom | Check First |
|---|---|
| No new device appears in Device Manager | Whether the cable supports data, the USB port/hub, device power supply |
| Device appears in Device Manager, but the software cannot find the port | Driver status, port refresh in the software, device model and connection mode |
| The software shows a COM port, but reports that the port cannot be opened | Whether the COM number is correct, whether the port is occupied by another program, whether the driver is abnormal |
| The device count changes or the device shows disconnected after repeated refreshes | USB contact, cable, power supply, stability of the port or hub |
| System resource error still appears after a restart | Keep the log and contact the supplier, attaching Device Manager and comparison test results |
Information to Prepare When Contacting Support
PowerWriter software name and version number, and the Windows version.
Device model, hardware version, and indicator or screen status.
The complete error log and the time it occurred; provide uncropped screenshots where possible.
The device name, COM number, driver version, and error status in Device Manager.
The USB port, data cable, or hub used, and whether cable/computer swap tests were performed.
Firmware package file name, source, applicable model, and the CRC32 / checksum information reported by the software.
The steps already attempted and the result of each step.